CATO 佳途CATO · CNAS + ANAB ISO 17034 双体系认可标准物质生产者CNAS + ANAB ISO 17034 dual-accredited reference material producer
销售顾问Sales contact 卢振明Kaka Lukaka@cato-chem.com
Calculator · nitrosamine limits

Nitrosamine limit calculator: from an intake in micrograms to a specification in ppm

Nitrosamine limits are set as an absolute daily intake, then converted to a concentration using the maximum daily dose. Enter a dose and read the concentration limit, the per-unit limit and the margin against a percentage-based specification.

Calculate

Concentration limit (single analyte)—ppm
Per unit limit—µg/unit
Margin against a 0.15% (1500 ppm) specification—× tighter
Allocated limit per analyte when sharing the intake—ppm

The third line exists to make one point concrete: a percentage limit written for organic impurities is not a nitrosamine limit. At a 500 mg dose, 0.15% allows 750 µg per day — five hundred times the 1.5 µg intake. A method can pass the percentage specification and still fail the intake by two orders of magnitude.

Reference table

Concentration equivalent of three common intake levels, by maximum daily dose. Values in ppm (mg/kg of drug substance).

Daily dose (mg)1.5 µg/day0.5 µg/day0.15 µg/day
11500600150
530012030
101506015
2560246
5030123
1001561.5
2007.530.75
25062.40.6
50031.20.3
10001.50.60.15

What the number does not cover

  • Summation. Where several nitrosamines are controlled against one intake, the limits are not applied independently; the fractions of the limit must sum to no more than one. The fourth output line allocates the intake evenly, which is the conservative case, not the regulatory rule for every product.
  • Dose expressed as salt. A 500 mg dose of a hydrochloride is not 500 mg of the free base. Convert first, then calculate, or the limit is wrong by the salt factor.
  • Method capability. A limit is only meaningful if the method reaches it. If the limit is 3 ppm and the validated quantification limit is 20 ppm, the specification is unverifiable and the method, not the limit, is the finding.
  • Formation on storage. A batch that passes at release can fail at the end of shelf life, because nitrosation continues in the package. Limits are set against the worst case, not the release result.